EFP1 Single Zone conventional fire alarm panel
- Installer-friendly design.
- Robust metal enclosure with heavy-duty base connections.
- One conventional Zone circuit
- Two conventional Sounder circuits.
- Separate indicators for open &Â short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire &Â non-latching fault outputs (via optional expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Multi-lingual variants (subject to quantities).
- Space for 2Â x 12V 2.3Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TECâs ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
Â
Technical Specifications
| Compatibility |
Designed to comply with the requirements of BS5839-4 (for head-out monitoring use 1 x BF378M module on the EFP1's zone circuit). |
|---|---|
| Mains supply |
230V 50/60Hz. |
| Internal power supply |
27V nominal. |
| Total output current limited to |
400mA @ 230V. |
| Quiescent current |
40mA (with no mains supply, detector and sounder EOLs fitted, no other loads supplied by panel). |
| Max battery size and type |
2 x 12V 2.3Ah VRLA connected in series. |
| No. of detector zone circuits |
1 (Max. length per circuit is 500m). |
| Call point resistor value |
470 to 680Ω. |
| Max. devices per detector zone |
20 detectors (max. detector current 2mA). No limit for manual call points. |
| No. of conventional sounder circuits |
2 (Max. length per circuit is 500m). |
| EOL resistor value |
6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
| Max. sounder output current |
400mA (to all outputs). Outputs are fused at 400mA. |
| Open collector outputs |
Available via optional expansion loom FF380X. |
| Auxiliary inputs |
Available via optional expansion loom FF380X. |
| Indicators |
Mains on; Zone Fire; Zone Fault; Sounder Fault; Battery/PSU Fault; O/C Zone Fault; S/C Zone Fault. |
| Controls |
External (keyswitch activated): Reset; Silence Alarm/Fault Sounders; Evacuate. Internal: Revert to S/C equals Fire. |
| Product dimensions (mm) |
271 W x 200 H x D 70mm. |
| Construction & finish |
Metal lid and base. |
| IP Rating |
IP30. |
| Weight |
2.3kg. |
| Operating conditions/temperature |
-5ÂșC to +40ÂșC. Max relative humidity: 95%.  |
Original: $208.74
-70%$208.74
$62.62Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
- Installer-friendly design.
- Robust metal enclosure with heavy-duty base connections.
- One conventional Zone circuit
- Two conventional Sounder circuits.
- Separate indicators for open &Â short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire &Â non-latching fault outputs (via optional expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Multi-lingual variants (subject to quantities).
- Space for 2Â x 12V 2.3Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TECâs ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
Â
Technical Specifications
| Compatibility |
Designed to comply with the requirements of BS5839-4 (for head-out monitoring use 1 x BF378M module on the EFP1's zone circuit). |
|---|---|
| Mains supply |
230V 50/60Hz. |
| Internal power supply |
27V nominal. |
| Total output current limited to |
400mA @ 230V. |
| Quiescent current |
40mA (with no mains supply, detector and sounder EOLs fitted, no other loads supplied by panel). |
| Max battery size and type |
2 x 12V 2.3Ah VRLA connected in series. |
| No. of detector zone circuits |
1 (Max. length per circuit is 500m). |
| Call point resistor value |
470 to 680Ω. |
| Max. devices per detector zone |
20 detectors (max. detector current 2mA). No limit for manual call points. |
| No. of conventional sounder circuits |
2 (Max. length per circuit is 500m). |
| EOL resistor value |
6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
| Max. sounder output current |
400mA (to all outputs). Outputs are fused at 400mA. |
| Open collector outputs |
Available via optional expansion loom FF380X. |
| Auxiliary inputs |
Available via optional expansion loom FF380X. |
| Indicators |
Mains on; Zone Fire; Zone Fault; Sounder Fault; Battery/PSU Fault; O/C Zone Fault; S/C Zone Fault. |
| Controls |
External (keyswitch activated): Reset; Silence Alarm/Fault Sounders; Evacuate. Internal: Revert to S/C equals Fire. |
| Product dimensions (mm) |
271 W x 200 H x D 70mm. |
| Construction & finish |
Metal lid and base. |
| IP Rating |
IP30. |
| Weight |
2.3kg. |
| Operating conditions/temperature |
-5ÂșC to +40ÂșC. Max relative humidity: 95%.  |