  • Multiple functionality in a single device – CO fire, smoke & heat multisensor fire detection plus an 86db(A) voice sounder – detects real fires quickly, reduces false alarms effectively and indicates true alarm conditions decisively.
  • Certified to EN54-3, 5, 7, 13, 17, 29 & 31 by Kiwa Telefication.
  • Compatible with C-TEC’s ZFP and XFP CAST protocol addressable fire panels.
  • MASC™ (Miniature Advanced Smoke Detection Chamber) and AFFIRM™ algorithms provide incredible tolerance to false alarms whilst enhancing the detection of real fire conditions.
  • Drift compensation functionality.
  • Onboard short circuit loop isolator.
  • Includes two 8mm x 2mm ultra-bright red LED indicating strips.
  • Multiple detection modes and different sensitivities for different times of the day.
  • Six selectable voice messages with tones (2 evacuate, 1 alert, 1 all clear & 2 system test messages).
  • 17.1mA max. alarm current (max vol, VAD on).
  • 630uA typical quiescent current @ 40V DC.
  • Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.

 

Technical Specifications

Approvals/certifications

Certified to EN54-13 by Kiwa Telefication., CPR number 0063-CPR-242190012, Kiwa Telefication certified to EN54-3, 5, 7, 17, 29 & 31

Compatibility

Compatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels.

Type

CO, Heat & Smoke Fire Detection plus Voice Sounder

Sensitivity

12 Detection Modes (default for this device is Mode 10).

Supply wiring

2-wire, polarity sensitive.

Supply/operating voltage

28 to 40V DC.

Quiescent current

630uA @ 40V.

Alarm current (Imax at Vmin)

17.1mA (max volume).

Alarm current (Iavg at Vmin)

9.1mA (max volume).

Sound pressure level (LAFmax) at Vmax at 1m

86dB(A).

VAD category & coverage

N/A.

Indicators

2 LED indicator strips emitting red light when in alarm offering 360º visibility. Optional remote LED.

Connections

Via CA408 base: 1 +Ve IN (analogue switch); 2 +Ve OUT (analogue switch); 3 Remote LED +Ve; 4 0V; 5 0V; 6 Screen; 7 Screen.

Product dimensions (mm)

105mm diameter x 48mm deep (detector only); 105mm diameter x 65mm deep (detector in base).

IP Rating

IP21C

Weight

125g (not in base); 180g (in base).

Operating conditions/temperature

-10ºC to +50ºC. Max relative humidity: 95% (non-condensing)

Notes

Requires a CA408 CAST base. CA408R relay base also available.  

$41.69

Original: $138.96

-70%
CAST PRO CO Fire + Smoke + Heat Multisensor c/w Voice Sounder

$138.96

$41.69

Product Information

Shipping & Returns

Description

  • Multiple functionality in a single device – CO fire, smoke & heat multisensor fire detection plus an 86db(A) voice sounder – detects real fires quickly, reduces false alarms effectively and indicates true alarm conditions decisively.
  • Certified to EN54-3, 5, 7, 13, 17, 29 & 31 by Kiwa Telefication.
  • Compatible with C-TEC’s ZFP and XFP CAST protocol addressable fire panels.
  • MASC™ (Miniature Advanced Smoke Detection Chamber) and AFFIRM™ algorithms provide incredible tolerance to false alarms whilst enhancing the detection of real fire conditions.
  • Drift compensation functionality.
  • Onboard short circuit loop isolator.
  • Includes two 8mm x 2mm ultra-bright red LED indicating strips.
  • Multiple detection modes and different sensitivities for different times of the day.
  • Six selectable voice messages with tones (2 evacuate, 1 alert, 1 all clear & 2 system test messages).
  • 17.1mA max. alarm current (max vol, VAD on).
  • 630uA typical quiescent current @ 40V DC.
  • Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.

 

Technical Specifications

Approvals/certifications

Certified to EN54-13 by Kiwa Telefication., CPR number 0063-CPR-242190012, Kiwa Telefication certified to EN54-3, 5, 7, 17, 29 & 31

Compatibility

Compatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels.

Type

CO, Heat & Smoke Fire Detection plus Voice Sounder

Sensitivity

12 Detection Modes (default for this device is Mode 10).

Supply wiring

2-wire, polarity sensitive.

Supply/operating voltage

28 to 40V DC.

Quiescent current

630uA @ 40V.

Alarm current (Imax at Vmin)

17.1mA (max volume).

Alarm current (Iavg at Vmin)

9.1mA (max volume).

Sound pressure level (LAFmax) at Vmax at 1m

86dB(A).

VAD category & coverage

N/A.

Indicators

2 LED indicator strips emitting red light when in alarm offering 360º visibility. Optional remote LED.

Connections

Via CA408 base: 1 +Ve IN (analogue switch); 2 +Ve OUT (analogue switch); 3 Remote LED +Ve; 4 0V; 5 0V; 6 Screen; 7 Screen.

Product dimensions (mm)

105mm diameter x 48mm deep (detector only); 105mm diameter x 65mm deep (detector in base).

IP Rating

IP21C

Weight

125g (not in base); 180g (in base).

Operating conditions/temperature

-10ºC to +50ºC. Max relative humidity: 95% (non-condensing)

Notes

Requires a CA408 CAST base. CA408R relay base also available.  

You may also like

-70%NEW
Thumbnail 1

Hochiki CHQ-PCM(SCI)

$122.05

$36.61

NEW
Thumbnail 1

Hochiki Male USB A to Male USB Micro B Cable, USB 2.0 1M (for device programming)

$7.80

NEW
Thumbnail 1

Hochiki ESP Device Programming Lead 3-WAY CONNECTOR

$7.49

NEW
Thumbnail 1Thumbnail 2

Hochiki Analogue Device Address Programmer TCH-B200

$106.66

NEW
Thumbnail 1

Hochiki Programming Lead (Jack Plug to Croc Clip)

$7.49

-70%NEW
Thumbnail 1

Hochiki Dual Input Module with SCI

$52.73

$15.82

-70%NEW
Thumbnail 1Thumbnail 2

Hochiki CHQ Module Box Lid

$4.85

$1.45

-70%NEW
Thumbnail 1

Hochiki Dual Input Module - DIN Enclosure with SCI

$62.14

$18.64

-70%NEW
Thumbnail 1

Hochiki Dual Relay Controller with SCI

$70.88

$21.26

-70%NEW
Thumbnail 1

Hochiki Sensor Mounting Base-White

$2.13

$0.64

NEW
Thumbnail 1Thumbnail 2

Hochiki CHQ Backbox Rated IP65

$8.62

NEW
Thumbnail 1Thumbnail 2

Hochiki Adaptor for New CHQ Modules

$3.63