šŸŽ‰ Up to 70% Off Selected ItemsShop Sale
Product image 1
HomeStore

CAST PRO CO Fire + Smoke + Heat Multisensor c/w Tone Sounder & O-C-1.9-4 Red VAD

CAST PRO CO Fire + Smoke + Heat Multisensor c/w Tone Sounder & O-C-1.9-4 Red VAD

  • Multiple functionality in a single device – CO fire, smoke & heat multisensor fire detection plus a 92db(A) tone Alarm sounder and an O-C-1.9-4 red VAD – detects real fires quickly, reduces false alarms effectively and indicates true alarm conditions decisively.
  • Certified to EN54-3, 5, 7, 13, 17, 23, 29 & 31 by Kiwa Telefication.
  • Compatible with C-TEC’s ZFP and XFP CAST protocol addressable fire panels.
  • MASCā„¢ (Miniature Advanced Smoke Detection Chamber) and AFFIRMā„¢ algorithms provide incredible tolerance to false alarms whilst enhancing the detection of real fire conditions.
  • Drift compensation functionality.
  • Onboard short circuit loop isolator.
  • Includes two 8mm x 2mm ultra-bright red LED indicating strips.
  • Multiple detection modes and different sensitivities for different times of the day.
  • 13.2mA max. alarm current (max vol, VAD on).
  • 630uA typical quiescent current @ 22-40V DC.
  • Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.

Ā 

Technical Specifications

Approvals/certifications

Certified to EN54-13 by Kiwa Telefication.,Ā CPR number 0063-CPR-212190016,Ā Kiwa Telefication certified to EN54-3, 5, 7, 17, 23, 29 & 31

Compatibility

Compatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels.

Type

CO, Heat & Smoke Fire Detection plus Tone Alarm & White VAD

Sensitivity

12 Detection Modes (default for this device is Mode 10).

Supply wiring

2-wire, polarity sensitive.

Supply/operating voltage

28 to 40V DC.

Quiescent current

630uA @ 40V.

Alarm current (Imax at Vmin)

13.2mA (max volume, VAD lit).

Alarm current (Iavg at Vmin)

10.8mA (max volume, VAD lit).

Sound pressure level (LAFmax) at Vmax at 1m

92dB(A).

VAD category & coverage

O-C-1.9-4 (2m2/mA efficiency; 0.5Hz Synchronised).

Indicators

2 LED indicator strips emitting red light when in alarm offering 360Āŗ visibility. Optional remote LED.

Connections

Via CA408 base: 1 +Ve IN (analogue switch); 2 +Ve OUT (analogue switch); 3 Remote LED +Ve; 4 0V; 5 0V; 6 Screen; 7 Screen.

Product dimensions (mm)

105mm diameter x 51mm deep (detector only); 105mm diameter x 68mm deep (detector in base).

IP Rating

IP21C

Weight

133g (not in base); 188g (in base).

Operating conditions/temperature

-10ĀŗC to +50ĀŗC. Max relative humidity: 95% (non-condensing)

Notes

Requires a CA408 CAST base. CA408R relay base also available.Ā Ā 

$41.00

Original: $136.66

-70%
CAST PRO CO Fire + Smoke + Heat Multisensor c/w Tone Sounder & O-C-1.9-4 Red VAD—

$136.66

$41.00

Product Information

Shipping & Returns

Description

  • Multiple functionality in a single device – CO fire, smoke & heat multisensor fire detection plus a 92db(A) tone Alarm sounder and an O-C-1.9-4 red VAD – detects real fires quickly, reduces false alarms effectively and indicates true alarm conditions decisively.
  • Certified to EN54-3, 5, 7, 13, 17, 23, 29 & 31 by Kiwa Telefication.
  • Compatible with C-TEC’s ZFP and XFP CAST protocol addressable fire panels.
  • MASCā„¢ (Miniature Advanced Smoke Detection Chamber) and AFFIRMā„¢ algorithms provide incredible tolerance to false alarms whilst enhancing the detection of real fire conditions.
  • Drift compensation functionality.
  • Onboard short circuit loop isolator.
  • Includes two 8mm x 2mm ultra-bright red LED indicating strips.
  • Multiple detection modes and different sensitivities for different times of the day.
  • 13.2mA max. alarm current (max vol, VAD on).
  • 630uA typical quiescent current @ 22-40V DC.
  • Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.

Ā 

Technical Specifications

Approvals/certifications

Certified to EN54-13 by Kiwa Telefication.,Ā CPR number 0063-CPR-212190016,Ā Kiwa Telefication certified to EN54-3, 5, 7, 17, 23, 29 & 31

Compatibility

Compatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels.

Type

CO, Heat & Smoke Fire Detection plus Tone Alarm & White VAD

Sensitivity

12 Detection Modes (default for this device is Mode 10).

Supply wiring

2-wire, polarity sensitive.

Supply/operating voltage

28 to 40V DC.

Quiescent current

630uA @ 40V.

Alarm current (Imax at Vmin)

13.2mA (max volume, VAD lit).

Alarm current (Iavg at Vmin)

10.8mA (max volume, VAD lit).

Sound pressure level (LAFmax) at Vmax at 1m

92dB(A).

VAD category & coverage

O-C-1.9-4 (2m2/mA efficiency; 0.5Hz Synchronised).

Indicators

2 LED indicator strips emitting red light when in alarm offering 360Āŗ visibility. Optional remote LED.

Connections

Via CA408 base: 1 +Ve IN (analogue switch); 2 +Ve OUT (analogue switch); 3 Remote LED +Ve; 4 0V; 5 0V; 6 Screen; 7 Screen.

Product dimensions (mm)

105mm diameter x 51mm deep (detector only); 105mm diameter x 68mm deep (detector in base).

IP Rating

IP21C

Weight

133g (not in base); 188g (in base).

Operating conditions/temperature

-10ĀŗC to +50ĀŗC. Max relative humidity: 95% (non-condensing)

Notes

Requires a CA408 CAST base. CA408R relay base also available.Ā Ā