CAST PRO CO Fire + Smoke + Heat Multisensor c/w Tone Sounder & C-3-9.4 White VAD
- Multiple functionality in a single device ā CO fire, heat & smoke multisensor fire detection plus a 92db(A) tone Alarm sounder and a C-3-9.4 VAD ā detects real fires quickly, reduces false alarms effectively and indicates true alarm conditions decisively.
- Certified to EN54-3, 5, 7, 13, 17, 23, 29 & 31 by Kiwa Telefication.
- Compatible with C-TECās ZFP and XFP CAST protocol addressable fire panels.
- MASC⢠(Miniature Advanced Smoke Detection Chamber) and AFFIRM⢠algorithms provide incredible tolerance to false alarms whilst enhancing the detection of real fire conditions.
- Drift compensation functionality.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Multiple detection modes and different sensitivities for different times of the day.
- 13.2mA max. alarm current (max vol, VAD on).
- 630uA typical quiescent current @ 22-40V DC.
- Compatible with C-TECās CA408 CAST base c/w integrated locking mechanism & ID tag.
- Want to see a demonstration of CAST-PRO in action? Register your interestĀ here.
Ā
Technical Specifications
| Approvals/certifications |
Certified to EN54-13 by Kiwa Telefication.,Ā CPR number 0063-CPR-212190016,Ā Kiwa Telefication certified to EN54-3, 5, 7, 17, 23, 29 & 31 |
|---|---|
| Compatibility |
Compatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels. |
| Type |
CO, Heat & Smoke Fire Detection plus Tone Alarm & White VAD |
| Sensitivity |
12 Detection Modes (default for this device is Mode 10). |
| Supply wiring |
2-wire, polarity sensitive. |
| Supply/operating voltage |
28 to 40V DC. |
| Quiescent current | |
| Alarm current (Imax at Vmin) |
13.2mA (max volume, VAD lit). |
| Alarm current (Iavg at Vmin) |
10.8mA (max volume, VAD lit). |
| Sound pressure level (LAFmax) at Vmax at 1m |
92dB(A). |
| VAD category & coverage |
C-3-9.4 (10m2/mA efficiency; 0.5Hz Synchronised). |
| Indicators |
2 LED indicator strips emitting red light when in alarm offering 360Āŗ visibility. Optional remote LED. |
| Connections |
Via CA408 base: 1 +Ve IN (analogue switch); 2 +Ve OUT (analogue switch); 3 Remote LED +Ve; 4 0V; 5 0V; 6 Screen; 7 Screen. |
| Product dimensions (mm) |
105mm diameter x 51mm deep (detector only); 105mm diameter x 68mm deep (detector in base). |
| IP Rating |
IP21C |
| Weight |
133g (not in base); 188g (in base). |
| Operating conditions/temperature |
-10ĀŗC to +50ĀŗC. Max relative humidity: 95% (non-condensing) |
| Notes |
Requires a CA408 CAST base. CA408R relay base also available.Ā Ā |
Original: $136.66
-70%$136.66
$41.00Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
- Multiple functionality in a single device ā CO fire, heat & smoke multisensor fire detection plus a 92db(A) tone Alarm sounder and a C-3-9.4 VAD ā detects real fires quickly, reduces false alarms effectively and indicates true alarm conditions decisively.
- Certified to EN54-3, 5, 7, 13, 17, 23, 29 & 31 by Kiwa Telefication.
- Compatible with C-TECās ZFP and XFP CAST protocol addressable fire panels.
- MASC⢠(Miniature Advanced Smoke Detection Chamber) and AFFIRM⢠algorithms provide incredible tolerance to false alarms whilst enhancing the detection of real fire conditions.
- Drift compensation functionality.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Multiple detection modes and different sensitivities for different times of the day.
- 13.2mA max. alarm current (max vol, VAD on).
- 630uA typical quiescent current @ 22-40V DC.
- Compatible with C-TECās CA408 CAST base c/w integrated locking mechanism & ID tag.
- Want to see a demonstration of CAST-PRO in action? Register your interestĀ here.
Ā
Technical Specifications
| Approvals/certifications |
Certified to EN54-13 by Kiwa Telefication.,Ā CPR number 0063-CPR-212190016,Ā Kiwa Telefication certified to EN54-3, 5, 7, 17, 23, 29 & 31 |
|---|---|
| Compatibility |
Compatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels. |
| Type |
CO, Heat & Smoke Fire Detection plus Tone Alarm & White VAD |
| Sensitivity |
12 Detection Modes (default for this device is Mode 10). |
| Supply wiring |
2-wire, polarity sensitive. |
| Supply/operating voltage |
28 to 40V DC. |
| Quiescent current | |
| Alarm current (Imax at Vmin) |
13.2mA (max volume, VAD lit). |
| Alarm current (Iavg at Vmin) |
10.8mA (max volume, VAD lit). |
| Sound pressure level (LAFmax) at Vmax at 1m |
92dB(A). |
| VAD category & coverage |
C-3-9.4 (10m2/mA efficiency; 0.5Hz Synchronised). |
| Indicators |
2 LED indicator strips emitting red light when in alarm offering 360Āŗ visibility. Optional remote LED. |
| Connections |
Via CA408 base: 1 +Ve IN (analogue switch); 2 +Ve OUT (analogue switch); 3 Remote LED +Ve; 4 0V; 5 0V; 6 Screen; 7 Screen. |
| Product dimensions (mm) |
105mm diameter x 51mm deep (detector only); 105mm diameter x 68mm deep (detector in base). |
| IP Rating |
IP21C |
| Weight |
133g (not in base); 188g (in base). |
| Operating conditions/temperature |
-10ĀŗC to +50ĀŗC. Max relative humidity: 95% (non-condensing) |
| Notes |
Requires a CA408 CAST base. CA408R relay base also available.Ā Ā |